Drager oxylog 2000 service manual




















If an alarm occurs, the these accordingly with the aid of exclamation table helps to identify causes and remedies. Confirm device has been pressed To switch OFF: confirm. OFF with rotary for 3 seconds. Patient "fights" the limits if necessary. Ventilation hose kinked, or Check hose system, breathing obstructed.

Disassemble the reusable hose system.. Remove the disposable hose system. If this is not done, the corrugations or hose may be torn from the sleeve. Page 89 Cleaning, Disinfection and Sterilization Breathing valve, disassembly 4 Disconnect the flow sensor A from the breath- 8 Turn the cover A about 90 ing valve.

Risk of CO rebreathing. Remove the disposable hose system 1 Disconnect flow measuring hoses A and B. Disinfectants based on: — Always exchange the disposable hose system — compounds containing alkylamine after use on a patient. Page Sterilizing The Reusable Hose System Cleaning, Disinfection and Sterilization Disinfecting by wiping Bath disinfection for reusable hose system Ventilator and medical gas hose: Disassembled parts of the breathing valve, flow sensor, ventilation hose and flow measuring hoses: — Follow the manufacturer's instructions.

Remove heavy soiling with a disposable cloth first. Page After Care Cleaning, Disinfection and Sterilization — Sterilization for longer than 10 minutes is permissible, but will decrease the service life of the hose system. After care — Reassemble, refer to the "Assembly" section for information. Page Maintenance Maintenance Maintenance Maintenance intervals In case of ventilator failure Page Maintenance Intervals Maintenance Maintenance intervals Inspection examination of actual condition.

Service measures to maintain specified condition. Repair measures to restore specified condition. Maintenance inspection, service, and repair, where necessary. Preventive maintenance measures at regular Maintenance intervals. In this case, always refer servicing to factory trained and authorized personnel. Page Disposal Disposal Disposal Safety information In order to comply with its registration, according to this directive, it may not be disposed of at municipal collection points for electrical and electronic equipment waste.

Page Ambient Conditions Technical Data WARNING Do not use the device outside the specified environmental and supply conditions, as the device may not operate according to its spec- ifications and may become inoperative.

Range of settings 0. Polycarbonate PC. Touch sensitive keypad on ventilator. Polyester film. Reusable hose system. Ventilation hose, flow Silicone rubber. Page Electromagnetic Emissions Technical Data Electromagnetic Emissions Electromagnetic Emissions The Oxylog plus is intended for use in the electromagnetic environment specified below. The user of the Oxylog plus should make sure that it is used in such an environment. Page Recommended Separation Distances Technical Data Recommended separation distances Recommendated separation distances between portable and mobile RF-Telecommunication devices and the Oxylog plus.

The table below gives examples of the most com- mon devices. If a device is not listed, do as follows: 1 Check the product manual of the device for the energy W and the frequency GHz values that the device transmits. The time for this pressure increase Slope is adjustable: — Page Functional Description Principles of Operation Functional description Microprocessor system Pressure control V6 Gas blender V1 - 3 S9 S7 The variable pneumatic actuators in the applied tidal volume corresponds with that set for Oxylog plus are controlled by the micropro- BTPS, taking into account the ambient pressure.

In cessor system via digitized electrical signals. Page Safety Principles of Operation Safety In the event of a fault, gas blender V closes and pressure control V6 opens to the atmosphere. The pneumatic demand valve NV spontaneous breath- ing opens in the presence of negative pressure. The pneumatic relief valve SV set to approximately 80 mbar opens in the presence of excess pressure.

Part name Part No. Reusable hose system, Workstation comprising: Oxylog plus 57 05 — Reusable hose system, 1. Page Index Screen Print page 1 Print document pages. Rename the bookmark. Delete bookmark? Cancel Delete. Delete from my manuals? Sign In OR. Don't have an account? Sign up! Thu Dec 03 Reply from Nealzal. Add your reply:. Sign in to Reply Submit Reply.

Draeger - Oxylog Plus by Draeger. Product Details. You are about to submit an abuse report for this post. Submit Abuse Report Cancel. This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Please review our Privacy Policy for more details. I Agree.

Site Links. The Oxylog features a compact and rugged design for portability and ease of use, as the ventilator is primarily used in emergency situations or during patient transport. It also supports both invasive and non-invasive ventilation. The Oxylog uses standardized disposable tubes, which are compatible with the Oxylog An LCD screen in conjunction with an analog pressure gauge supply the operator with all the volume, pressure, and frequency information they need.

Fix Your Stuff Community Store.